BC-P Single point load cell, 150kgf - 500kgf
¢ÁFEATURES NTEP III 5,000S approved(Handbook 44) OIML C3 approved(OIML R60) Off center compensated(OIML R76) Protection class IP65
¢ÁOPTIONS NTEP III 5,000S approved(A5) OIML C3 approved(C3) 6-wires connection
¢ÁMaterial Anodized Aluminum
¢ÁMounting Socket-head cap screw 5/16-18UNC(10.9) Tightening torque: 29Nm
¢ÁCable Braided Shield 4-wire round cable with PVC-Jacket
¢ÁMaximum Platform Size 600 x 600mm
¢ÁOrdering Information BCM - XXXL - I ¦¬¦³ Capacity in kg
Max. capacity
|
kgf
|
50, 75, 100, 150, 200, 300, 500
|
Rated output
|
mV/ V
|
1.2 (Approx.)
|
Zoro balance
|
mV/ V
|
0 ¡¾ 0.06
|
Accuracy class
|
¡¡
|
D3
|
C3, A5
|
Combined error
|
%
|
0.03
|
0.02
|
Repeatability
|
%
|
0.01
|
0.01
|
Creep for 30min.
|
%
|
0.03
|
0.017
|
Temperature effect on
|
¡¡
|
¡¡
|
¡¡
|
Zero Value
|
%/ 10¡É
|
0.04
|
0.014
|
Output value
|
%/ 10¡É
|
0.015
|
0.011
|
Excitation
|
¡¡
|
¡¡
|
Recommended
|
V
|
10
|
Maximum
|
V
|
15
|
Resistance
|
¡¡
|
¡¡
|
Input
|
¥Ø
|
400 ¡¾ 20
|
Output
|
¥Ø
|
350 ¡¾ 3.5
|
Insulation
|
M¥Ø
|
£¾2,000
|
Compensated temperature range
|
¡É
|
-10 to +40
|
Operating temperature range
|
¡É
|
-20 to +70
|
|
|